100W High Voltage Modules

HW Series

The HW series of high power high voltage modules covers the range from 1 kV to 50 kV giving 100 watts of output power. Control of the output voltage is by internal potentiometer, external potentiometer or by external 10 volt analogue control voltage. Pins 1 to 10 of the 12 pin Molex input connector are compatible with both the high precision HP series and the general purpose KS series.

 

All units are short circuit proof and use high frequency pulse width modulated switching techniques, in conjunction with a ferrite step-up transformer to control the output voltage. The units operate from a 24 volt input and have an efficiency of around 80%.

Features include: 1kV, 2.5kV, 5kV, 10kV, 30kV, 40kV & 50kV output range, high efficiency, high frequency switch mode control, internal control or externally programmable, short circuit and flashover proof, 24 hour burn in, safety assessed to EN61010-1


Unit Type Polarity Output Ripple at full load
HW1/100P Positive 50 volts to 1kV at 100mA <0.1% peak to peak
HW1/100N Negative
HW2.5/40P Positive 100 volts to 2.5kV at 40mA <0.1% peak to peak
HW2.5/40N Negative
HW5/20P Positive 250volts to 5kV at 20mA <0.1% peak to peak
HW5/20N Negative
HW10/10P Positive 500 volts to 10kV at 10mA <0.1% peak to peak
HW10/10N Negative
HW30/3P Positive 1.5kV to 30kV at 3mA <0.1% peak to peak
HW30/3N Negative
HW40/2.5P Positive 2kV to 40kV at 2.5mA <0.5% peak to peak (500pF load)
HW40/2.5N Negative
HW50/2P Positive 3kV to 50kV at 2mA <0.5% peak to peak (500pF load)
HW50/2N Negative

Electrical Specification
Input voltage: 24 volt d.c. ±10% at 6A. Negative input terminal common to HV earth return.
Output Voltage: See table.
Line Regulation: Less than 0.1% of maximum voltage for input changes of 1 volt.
Load regulation: Less than 0.1% for load changes from 10% to maximum. (Measured at maximum voltage).
On/Off: Unit operates when pin 8 is low (<1.5V). This also resets the trip.
Overload Protection: Flashover and short circuit proof. Trip on over current, reset by on/off.
Temperature co-efficient: 300ppm/°C or better.
Control: INTERNAL potentiometer. EXTERNAL potentiometer or 10V analogue signal. (0 to +10V gives zero to maximum output). Input impedance > 10Kohm.
Readout: Voltage monitor 0 to +10V represents zero to maximum output
(source resistance 10 kohm).
Current monitor 0 to +10V represents zero to maximum current
(source resistance 10 kohm).
N.B. Current monitor (supplied as standard) includes the internal feedback current of about 100 uA. Precision I monitor (available as an option) removes this current to give a true reading of load current.
Operating temperature: 0°C to +45°C.
Storage temperature: -35°C to +85°C.
R.F.I.: Choke input filter. Steel case for low radiated magnetic field.
Safety: Meets or exceeds the requirements of EN61010-1.
Mechanical Specification
Size: All units 230 x 135 x 60 mm (except HW40/2.5 and HW50/2 size 280 x 135 x 60mm).
Output: By 0.5 metre screened cable (1 metre on HW30/3, HW40/2.5 and HW50/2).
Input Connnector: Molex 12 pin (mating connector supplied).