High Power 250 Watt High Voltage Modules

KW Series

The KW series of mains operated high power, high voltage modules covers the range from 1kV to 15kV giving 250 watts of output power. All units are short circuit proof and have low stored energy. They use high frequency pulse width modulated switching techniques in conjunction with a ferrite step-up transformer to control the output voltage.

Control of the output voltage and the trip level is by internal potentionmeter, external potentionmeter or by external 0 to 10 volt analogue control voltage.

 

Features include: 1kV, 2.5kV, 5kV, 10kV & 15kV output range, Off line, high frequency switch mode system, Internal control or externally programmable, Short circuit and flashover proof, 24 hour burn in, High efficiency

Applications include: Lasers, Capacitor charging, Ion pumps, X-ray, Ion implantation


Unit Type Polarity Output Ripple at full load
KW1/250P Positive 50 volts to 1kV at 250mA Better than 0.25%
peak to peak
KW1/250N Negative
KW2.5/100P Positive 100 volts to 2.5kV at 100mA
KW2.5/100N Negative
KW5/50P Positive 250 volts to 5kV at 50mA
KW5/50N Negative
KW10/25P Positive 500 volts to 10kV at 25mA
KW10/25N Negative
KW15/16P Positive 750 volts to 15kV at 16mA
KW15/16N Negative

Electrical Specification
Input voltage: 200 to 264 volt A.C. 50/60 Hz at 4.5A RMS. (110V option to special order).
Output Voltage Control: By internal potentiometer, external potentiometer or by analogue signal such that 0 to +10V gives 0 to maximum output.
Ripple: Better than 0.25% peak to peak. (0.1% ripple or better to special order).
Line Regulation: Better than 0.1% for ±10% change.
Load regulation: Better than 0.1% for load changes from 10% to maximum.
Temperature co-efficient: 300ppm/°C or better.
Voltage monitor: 0 to +10V represents 0 to maximum voltage.
Current Monitor: 0 to +10V represents 0 to maximum current.
Current Trip Control: Variable by internal potentiometer, external potentiometer or by analogue signal such that 0 to +10V sets 0 to maximum trip level.
Operating Temperature: 0 °C to +45°C
Storage Temperature: -35°C to +85°C.
E.M.C.: To EN55011.
Safety: To EN60950.
Mechanical Specification
Size: 365 x 220 x 76 mm
Output: By flying lead type URM43.
Weight: 6kg.
Input: Mains by flying lead 2 meters long. Control by D type connector.