| D.C. Linear Regulated Power Supply
Model 6218 D.C. Linear Regulated Power Supply available in single or dual output configurations and in fixed voltages from 5 volts to 48 volts. The regulators are temperature limited and time dependant current limited. The power supply incorporates a toriodal transformer which gives the unit a low weight and small size. Other advantages are low external field and elimination of transformer hum. |
![]() |
| Specifications | |
| Input Volts: | 240 Volts 50/60 Hz, 110 Volts 50/60 Hz (available) |
| Load Regulation: | Better than 0.5% no load to full load |
| Line Regulation: | Better than 0.5% for 10% change in input volts |
| Total Noise: | Less than 20mV R.M.S. |
| Protection: | None. Input fuses should be rated 5 to 10 times full load input current |
| Current Limit: | 2 A approx. (7A for 2A models) Output is short circuit protected for models up to 24 volts |
| Ambient Range: | 0° - 55° Celsius |
| Dimensions: | See below |
| Model | Output Volts D.C. |
Output Amps D.C. |
Typical full load input current* |
Weight kg |
| 6218-X0 6218-X00 6218-X1 6218-X11 6218-X22 6218-X33 6218-X4 6218-X44 6218-X7 |
5 ±5 12 ±12 ±15 ±18 24 ±24 48 |
2.0 1.2 1.2 1.2 1.2 1.2 1.2 0.6 0.5 |
0.05 0.10 0.10 0.17 0.18 0.19 0.18 0.18 0.25 |
1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 |
| X = 0 for 110 Volts 50 Hz, X = 2 for 240 Volts 50 Hz, * 240V Input |
Mains Input Variation: The power supply can be used at full current down to an input voltage of 210 Volts, however at low input voltages (below 240 volts) the output ripple will increase if the output current exceeds nominal output X [mains input voltage-190]/50. The Model 6218-20 power supply will give full output performance for voltages from 210 to 245. All power supplies can be used up to 255 Volts input, however above 245 Volts the maximum ambient temperature must be reduced by [mains input voltage-245] x 1degree celcius per volt. Non-standard Voltages: These power supplies are available in non-standard input and output voltages. Mounting: For maximum power out mount with the longest dimension vertical. Do not obstruct airflow. |

| Click here to enquire about this product | Amalgen Homepage |
|
Amalgen Technologies Pty Ltd 43 Anderson Road, Mortdale NSW 2223 Australia Phone: +61 2 9570 2855 Fax: +61 2 9580 5128 |
| © 2007 All rights reserved. Amalgen Technologies Pty Ltd. |